Product introduction
1:Fixed rack 2:Support frame 3:Discharge pipe 4:Left and right adjusting lever 5:Eddy current flaw detector
6:Front and rear trimming 7:Upper and lower trimming 8:Collision avoidance device 9:Eddy current probe
Performance
Test beat |
Large rollers, 60pieces/min; Medium rollers, 120pieces/min; Small rollers, 180 grains/min |
Detection speed |
1~3pieces/s |
Frequency range |
10Hz~10MHz |
Gain |
0~99dB,side size 0.1dB |
Advanced filtering |
Yes |
High pass |
0.1Hz~650Hz |
Low pass |
1Hz~10000Hz |
Phase rotation |
0-360° side size 1° |
Flaw detection accuracy |
Crack length * width * depth (3 * 0.01 * 0.05) mm |
Synchronized alarm output controlled by internal and external clock |
High Precision End and End Signal Excision Function |
High Precision Real-time and Delayed Alarm Output |
Fast Digital/Analog Electronic Balance |
Delayed Hidden Removal Function with Memory Trajectory |
Real-time impedance plane display |
The instrument can match any probe |
Remote Automatic Help System |
Man-machine interface in Chinese and English |
Non-equal Amplitude Phase/Amplitude Alarm Domain |
Computer Full Digital Parameter Adjustment |
Automatic Statistics of Total, Bad Products, Qualified Number |