Product introduction
The piston rod above is driven by two cots rotating in the same direction, and the piston rod is driven by the pusher rod to complete the detection from under the probe.
Piston rod status and parameters
1. Piston rod specification φ10-φ28, length 100-500.
2、Piston rod material: ordinary carbon steel, alloy round steel.
3、Piston rod status: roughness Ra0.1, roundness 0.02, circular jump 0.07.
4、Detection speed: Take the workpiece diameter 20, length 450, detection distance 300 as an example, detection rhythm 6 seconds.
5、Detection location: the largest diameter of the outer circle.
6、Detection accuracy: cracks of 0.1 mm (depth) x 0.1 mm (width) x 3 mm (length)
7、Workpiece rotation speed: According to the detection speed, the piston rod rotates one cycle, and the propulsion distance is 3-5 mm.
Piston rod status and parameters
1. Piston rod specification φ10-φ28, length 100-500.
2、Piston rod material: ordinary carbon steel, alloy round steel.
3、Piston rod status: roughness Ra0.1, roundness 0.02, circular jump 0.07.
4、Detection speed: Take the workpiece diameter 20, length 450, detection distance 300 as an example, detection rhythm 6 seconds.
5、Detection location: the largest diameter of the outer circle.
6、Detection accuracy: cracks of 0.1 mm (depth) x 0.1 mm (width) x 3 mm (length)
7、Workpiece rotation speed: According to the detection speed, the piston rod rotates one cycle, and the propulsion distance is 3-5 mm.
Performance
Detection channel |
4 channels |
Detection speed |
1-30m/min |
Frequency range |
100Hz-1MHz |
Gain |
40-99Db,adjustment 0.1Db/ block |
Advanced filtering |
Yes |
High pass |
0.1Hz~650Hz |
Low pass |
1Hz~10000Hz |
Phase rotation |
0-360° side size1° |
Gas source |
≥4bar,traffic 20L/min |
Ambient temperature |
-20℃-40℃ |
Power |
180V-240V 50Hz |
Computer Full Digital Parameter Adjustment |
Synchronized alarm output controlled by internal and external clock |
High Precision End and End Signal Excision Function |
High Precision Real-time and Delayed Alarm Output |
Fast Digital/Analog Electronic Balance |
Delayed Hidden Removal Function with Memory Trajectory |
Real-time impedance plane display |
The instrument can match any probe |
Remote Automatic Help System |
Man-machine interface in Chinese and English |
Multi-amplitude Phase/Amplitude Alarm Domain |
Provide X-t, Y-t, V-t three time-based scanning real-time display mode options |
Windows Operating Interface, Modular Man-Machine Dialogue |
The instrument can be connected with the PLC of the transmission mechanism |
The distance between the induction probe and the workpiece is kept at 0.5-2 mm |
Intelligent Warning for Fault Detection Equipment |
Multi-class interfaces can be reserved to facilitate the integration of mechanical operation |
Four probes can give signals and alarm separately |
The equipment is a four-channel independent intelligent eddy current flaw detector. Four probes under control collect and control work independently |